Timeline for Analog thermistor readings are wrong
Current License: CC BY-SA 4.0
4 events
when toggle format | what | by | license | comment | |
---|---|---|---|---|---|
Jun 13, 2019 at 11:48 | vote | accept | marsisalie | ||
Jun 13, 2019 at 11:48 | comment | added | marsisalie | I was able to figure out a function to calculate the offset - since there is an acceptable relation between measured and expected, whatever thermistors, Arduino boards, cables/wire or breadboards we are using. Your range suggestions for the offset helped to calibrate our curves. | |
Jun 12, 2019 at 11:59 | history | edited | Edgar Bonet | CC BY-SA 4.0 |
+ link to post on ADC calibration
|
Jul 15, 2017 at 13:37 | history | answered | Edgar Bonet | CC BY-SA 3.0 |